Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Radiat Oncol ; 19(1): 51, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649902

RESUMO

BACKGROUND: Radiation-induced liver damage (RILD) occasionally occurs following carbon-ion radiotherapy (CIRT) for liver tumors, such as hepatocellular carcinoma (HCC), in patients with impaired liver function disease. However, the associated risk factors remain unknown. The present study aimed to determine the risk factors of RILD after CIRT. METHODS: We retrospectively analyzed 108 patients with HCC treated with CIRT at the Osaka Heavy Ion Therapy Center between December 2018 and December 2022. RILD was defined as a worsening of two or more points in the Child-Pugh score within 12 months following CIRT. The median age of the patients was 76 years (range 47-95 years), and the median tumor diameter was 41 mm (range 5-160 mm). Based on the pretreatment liver function, 98 and 10 patients were categorized as Child-Pugh class A and B, respectively. We analyzed patients who received a radiation dose of 60 Gy (relative biological effectiveness [RBE]) in four fractions. The median follow-up period was 9.7 months (range 2.3-41.1 months), and RILD was observed in 11 patients (10.1%). RESULTS: Multivariate analysis showed that pretreatment Child-Pugh score B (p = 0.003, hazard ratio [HR] = 6.90) and normal liver volume spared from < 30 Gy RBE (VS30 < 739 cm3) (p = 0.009, HR = 5.22) were significant risk factors for RILD. The one-year cumulative incidences of RILD stratified by Child-Pugh class A or B and VS30 < 739 cm3 or ≥ 739 cm3 were 10.3% or 51.8% and 39.6% or 9.2%, respectively. CONCLUSION: In conclusion, the pretreatment Child-Pugh score and VS30 of the liver are significant risk factors for RILD following CIRT for HCC.


Assuntos
Carcinoma Hepatocelular , Radioterapia com Íons Pesados , Neoplasias Hepáticas , Lesões por Radiação , Humanos , Neoplasias Hepáticas/radioterapia , Carcinoma Hepatocelular/radioterapia , Radioterapia com Íons Pesados/efeitos adversos , Idoso , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Prognóstico , Lesões por Radiação/etiologia , Lesões por Radiação/patologia , Fatores de Risco , Fígado/efeitos da radiação , Fígado/patologia
2.
Plant Reprod ; 36(3): 273-284, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37227496

RESUMO

Hybridization plays an indispensable role in creating the diversity associated with plant evolution and genetic improvement of crops. Production of hybrids requires control of pollination and avoidance of self-pollination for species that are predominantly autogamous. Hand emasculation, male sterility genes or male gametocides have been used in several plant species to induce pollen sterility. However, in cowpea (Vigna unguiculata (L.) Walp), a self-pollinated cleistogamous dryland crop, only hand emasculation is used, but it is tedious and time-consuming. In this study, male sterility was effectively induced in cowpea and two dicotyledonous model species (Arabidopsis thaliana (L.) Heynh. and Nicotiana benthamiana Domin) using trifluoromethanesulfonamide (TFMSA). Pollen viability assays using Alexander staining showed that 30 ml of 1000 mg/l TFMSA with two-time treatments of one-week interval at the early stage of the reproductive phase under field or greenhouse conditions induced 99% pollen sterility in cowpea. TFMSA treatment induced non-functional pollen in diploid A. thaliana at two-time treatment of 10 ml of 125-250 mg/l per plant and N. benthamiana at two-time treatment of 10 ml of 250-1000 mg/l per plant. TFMSA-treated cowpea plants produced hybrid seeds when used as the female parent in crosses with non-treated plants used as male parents, suggesting that TFMSA had no effect on female functionality in cowpea. The ease of TFMSA treatment and its effectiveness to induce pollen sterility in a wide range of cowpea genotypes, and in the two model plant species tested in this study, may expand the scope of techniques for rapid pollination control in self-pollinated species, with potential applications in plant breeding and plant reproduction science.


Assuntos
Infertilidade Masculina , Magnoliopsida , Vigna , Masculino , Humanos , Vigna/genética , Melhoramento Vegetal , Magnoliopsida/genética , Genes de Plantas , Infertilidade Masculina/genética
3.
Front Plant Sci ; 12: 729734, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34475879

RESUMO

Polyploidization is an evolutionary event leading to structural changes of the genome(s), particularly allopolyploidization, which combines different genomes of distinct species. The tetraploid species, Sorghum halepense, is assumed an allopolyploid species formed by hybridization between diploid S. bicolor and S. propinquum. The repeat profiles of S. bicolor, S. halepense, and their relatives were compared to elucidate the repeats' role in shaping their genomes. The repeat frequencies and profiles of the three diploid accessions (S. bicolor, S. bicolor ssp. verticilliflorum, and S. bicolor var. technicum) and two tetraploid accessions (S. halepense) are similar. However, the polymorphic distribution of the subtelomeric satellites preferentially enriched in the tetraploid S. halepense indicates drastic genome rearrangements after the allopolyploidization event. Verified by CENH3 chromatin immunoprecipitation (ChIP)-sequencing and fluorescence in situ hybridization (FISH) analysis the centromeres of S. bicolor are mainly composed of the abundant satellite SorSat137 (CEN38) and diverse CRMs, Athila of Ty3_gypsy and Ty1_copia-SIRE long terminal repeat (LTR) retroelements. A similar centromere composition was found in S. halepense. The potential contribution of S. bicolor in the formation of tetraploid S. halepense is discussed.

4.
J Appl Clin Med Phys ; 19(2): 144-153, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29369463

RESUMO

PURPOSE: We developed a system for calculating patient positional displacement between digital radiography images (DRs) and digitally reconstructed radiography images (DRRs) to reduce patient radiation exposure, minimize individual differences between radiological technologists in patient positioning, and decrease positioning time. The accuracy of this system at five sites was evaluated with clinical data from cancer patients. The dependence of calculation accuracy on the size of the region of interest (ROI) and initial position was evaluated for clinical use. METHODS: For a preliminary verification, treatment planning and positioning data from eight setup patterns using a head and neck phantom were evaluated. Following this, data from 50 patients with prostate, lung, head and neck, liver, or pancreatic cancer (n = 10 each) were evaluated. Root mean square errors (RMSEs) between the results calculated by our system and the reference positions were assessed. The reference positions were manually determined by two radiological technologists to best-matching positions with orthogonal DRs and DRRs in six axial directions. The ROI size dependence was evaluated by comparing RMSEs for three different ROI sizes. Additionally, dependence on initial position parameters was evaluated by comparing RMSEs for four position patterns. RESULTS: For the phantom study, the average (± standard deviation) translation error was 0.17 ± 0.05, rotation error was 0.17 ± 0.07, and ΔD was 0.14 ± 0.05. Using the optimal ROI size for each patient site, all cases of prostate, lung, and head and neck cancer with initial position parameters of 10 mm or under were acceptable in our tolerance. However, only four liver cancer cases and three pancreatic cancer cases were acceptable, because of low-reproducibility regions in the ROIs. CONCLUSION: Our system has clinical practicality for prostate, lung, and head and neck cancer cases. Additionally, our findings suggest ROI size dependence in some cases.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia com Íons Pesados , Neoplasias Hepáticas/radioterapia , Neoplasias Pulmonares/radioterapia , Neoplasias Pancreáticas/radioterapia , Posicionamento do Paciente , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Humanos , Imagens de Fantasmas , Prognóstico , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos
5.
Igaku Butsuri ; 37(3): 181-185, 2017.
Artigo em Japonês | MEDLINE | ID: mdl-29415961

RESUMO

A three-dimensional dosimetry method is strongly required in the dose distribution measurement of a patient QA of a heavy ion therapy. Nanocomposite Fricke gel dosimeters are the most possible candidate for this purpose. Experimental dose distribution measurements were carried out using a scanning irradiation port of Gunma University Heavy Ion Medical Center. The result showed no significant LET dependence and indicated a possibility for a precise dosimetry of a heavy ion therapy. It also indicated the importance of three-dimensional dosimetry in the commissioning process of the treatment accelerator.


Assuntos
Carbono , Dosímetros de Radiação , Humanos , Radiometria
6.
Asian Spine J ; 10(3): 522-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27340533

RESUMO

STUDY DESIGN: Case-control study. PURPOSE: To evaluate the surgical magnitude and learning curve of "second-generation" total en bloc spondylectomy (TES). OVERVIEW OF LITERATURE: In June 2010, we developed second-generation TES combined with tumor-induced cryoimmunology, which does not require autograft harvesting. METHODS: TES was performed in 63 patients between June 2010 and September 2013. Three groups of patients were evaluated: 20 undergoing surgery in the first year of development of second-generation TES (group I), 20 in the second year (group II), and 23 in the third year (group III). Patient backgrounds showed no remarkable differences. Operating time, intraoperative blood loss, blood transfusion, and postoperative C-reactive protein and creatine phosphokinase were compared among the groups. RESULTS: Mean±standard deviation operating time was 486±130 minutes in group I, 441±85 minutes in group II, and 396±75 minutes in group III. The time was significantly shorter in group III than in group I (p<0.05). Intraoperative blood loss was 901±646 mL in group I, 433±177 mL in group II, and 411±167 mL in group III. Blood loss was significantly lower in groups II and III than in group I (p<0.01). Transfusion was not required in 20 of 23 patients in group III, and mean C-reactive protein levels on postoperative day 3 were significantly lower in this group than in group I (6.12 mg/L vs. 10.07 mg/L; p<0.05). Postoperative creatine phosphokinase levels did not differ among the groups. CONCLUSIONS: TES is associated with a significant learning curve. Thus, second-generation TES can no longer be considered highly invasive.

7.
Chromosome Res ; 24(3): 285-97, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27072826

RESUMO

Genome instability is observed in several species hybrids. We studied the mechanisms underlying the genome instability in hexaploid hybrids of Napier grass (Pennisetum purpureum R.) and pearl millet (Pennisetum glaucum L.) using a combination of different methods. Chromosomes of both parental genomes are lost by micronucleation. Our analysis suggests that genome instability occurs preferentially in meristematic root tissue of hexaploid hybrids, and chromosome elimination is not only caused by centromere inactivation. Likely, beside centromere dysfunction, unrepaired DNA double-strand breaks result in fragmented chromosomes in synthetic hybrids.


Assuntos
Centrômero/metabolismo , Cromossomos de Plantas/genética , Instabilidade Genômica/genética , Meristema/genética , Pennisetum/genética , Raízes de Plantas/genética , Quimera/genética , Quebras de DNA de Cadeia Dupla , Hibridização Genética , Hibridização in Situ Fluorescente , Micronúcleos com Defeito Cromossômico , Melhoramento Vegetal , Poliploidia
8.
Orthopedics ; 38(7): e561-6, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26186316

RESUMO

Cerebrospinal fluid (CSF) leakage is a serious postoperative complication associated with total en bloc spondylectomy. The authors examined the risk factors for CSF leakage after this procedure. A total of 72 patients underwent total en bloc spondylectomy at the authors' institution between May 2010 and April 2013. Postoperative CSF leakage was observed in 17 of the 72 patients (23.6%). The results of univariate analysis suggested that age 54 years or older, preoperative surgical site irradiation, resection of 3 or more vertebral bodies, and dural injury were significant risk factors for postoperative CSF leakage after total en bloc spondylectomy. Multivariate analysis showed that preoperative surgical site irradiation was the only significant risk factor for postoperative CSF leakage (adjusted odds ratio, 5.22; 95% confidence interval, 1.03-26.45, P=.046). The authors also assessed the course of treatment for postoperative CSF leakage in each patient. Of 17 patients with postoperative CSF leakage, 13 recovered without further complications, but 4 required reoperation (2 for wound dehiscence, 1 for surgical site infection, and 1 for severe intracranial hypotension). All 4 patients who required reoperation had a history of surgical site irradiation. Thus, this study suggests that careful consideration should be given to postoperative CSF leakage in patients with a history of surgical site irradiation. These findings may contribute to the management of postoperative CSF leakage associated with total en bloc spondylectomy and supplement the information given to the patient in the process of obtaining informed consent.


Assuntos
Vazamento de Líquido Cefalorraquidiano/etiologia , Osteotomia/efeitos adversos , Neoplasias da Coluna Vertebral/cirurgia , Vazamento de Líquido Cefalorraquidiano/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/métodos
9.
J Appl Clin Med Phys ; 16(4): 100­111, 2015 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-26219004

RESUMO

Highly accurate radiotherapy needs highly accurate patient positioning. At our facility, patient positioning is manually performed by radiology technicians. After the positioning, positioning error is measured by manually comparing some positions on a digital radiography image (DR) to the corresponding positions on a digitally reconstructed radiography image (DRR). This method is prone to error and can be time-consuming because of its manual nature. Therefore, we propose an automated measuring method for positioning error to improve patient throughput and achieve higher reliability. The error between a position on the DR and a position on the DRR was calculated to determine the best matched position using the block-matching method. The zero-mean normalized cross correlation was used as our evaluation function, and the Gaussian weight function was used to increase importance as the pixel position approached the isocenter. The accuracy of the calculation method was evaluated using pelvic phantom images, and the method's effectiveness was evaluated on images of prostate cancer patients before the positioning, comparing them with the results of radiology technicians' measurements. The root mean square error (RMSE) of the calculation method for the pelvic phantom was 0.23 ± 0.05 mm. The coefficients between the calculation method and the measurement results of the technicians were 0.989 for the phantom images and 0.980 for the patient images. The RMSE of the total evaluation results of positioning for prostate cancer patients using the calculation method was 0.32 ± 0.18 mm. Using the proposed method, we successfully measured residual positioning errors. The accuracy and effectiveness of the method was evaluated for pelvic phantom images and images of prostate cancer patients. In the future, positioning for cancer patients at other sites will be evaluated using the calculation method. Consequently, we expect an improvement in treatment throughput for these other sites.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Posicionamento do Paciente , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Erros de Configuração em Radioterapia/prevenção & controle , Automação , Humanos , Masculino , Pelve/diagnóstico por imagem , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos
10.
Orthopedics ; 38(6): e520-3, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26091226

RESUMO

For spinal fusion or the correction of spine deformity at multiple levels, intraoperative rod contouring is required to realign the spine. A French bender is the most common contouring tool used. There are several reports on the mechanical properties of various rods with manufactured straight rod; however, few reports describe the changes in a rod's mechanical properties after rod contouring. The authors investigated the influences of rod contouring on rod strength and stiffness. A 3-point bending test was conducted. Each 18-cm rod was loaded at a rate of 10 mm/min with a load applicator. Three different rod diameters (5.5, 6.0, and 6.35 mm) and 2 types of materials (titanium [Ti] alloy and cobalt-chromium [CoCr] alloy) were assessed. Different rod curvatures were evaluated: (1) a no-preparation rod of 0° (control); (2) a 0° rod bent at one point to make tangential angles of 10° and then bent back from the opposite side; (3) a bent rod with tangential angles of 20°; and (4) a 40° bent rod. The yield strength in all types of rod materials and diameter decreased after rod contouring using a French bender. The extent of decrease depended on the degree of bend. The bending stiffness of each rod also decreased. The CoCr rod showed higher bending stiffness than the Ti rod of the same diameter. Rod contouring using a French bender reduced the yield strength and stiffness in all types of rods. Decrease of yield strength correlated to the degree of bend. In the comparison of 20° and 40° contoured rods, the 6.0-mm CoCr rod showed the highest reduction force. This study found that rod contouring procedures reduced rod yield strength and stiffness.


Assuntos
Curvaturas da Coluna Vertebral/cirurgia , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Humanos , Teste de Materiais/métodos , Fusão Vertebral/instrumentação , Titânio
11.
Spine J ; 15(1): 132-7, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25131266

RESUMO

BACKGROUND CONTEXT: Surgical site infection (SSI) associated with instruments remains a serious and common complication in patients who undergo total en bloc spondylectomy (TES). It is very important that the risk factors for SSI are known to prevent it. PURPOSE: The purpose of the study was to identify independent risk factors for SSI after TES and evaluate the positive effect of iodine-supported spinal instruments in the prevention of SSI after TES. STUDY DESIGN: This is a retrospective clinical study. PATIENT SAMPLE: One hundred twenty-five patients who underwent TES for vertebral tumor were evaluated. OUTCOME MEASURES: Incidence rate of SSI, risk factors for SSI after TES, and safety of iodine-supported spinal instruments were the outcome measures. METHODS: Risk factors for SSI were analyzed using logistic regression. In recent 69 patients with iodine-supported spinal instruments, the thyroid hormone levels in the blood were examined to confirm if iodine from the implant influenced thyroid function. Postoperative radiological evaluations were performed regularly. RESULTS: The rate of SSI was 6.4% (8/125 patients). By multivariate logistic regression, combined anterior and posterior approach and nonuse of iodine-supported spinal instruments were associated with an increased risk of SSI. The rate of SSI without iodine-supported spinal instruments was 12.5%, whereas the rate with iodine-supported spinal instruments was 1.4%. This difference was statistically significant. There were no detected abnormalities of thyroid gland function with the use of iodine-supported instruments. Among the 69 patients with iodine-supported spinal instruments, 2 patients required additional surgery because of instrument failure. However, there were no obvious involvements with the use of iodine-supported spinal instruments. CONCLUSIONS: This study identified combined anterior and posterior approach and nonuse of iodine-supported spinal instruments to be independent risk factors for SSI after TES. Iodine-supported spinal instrument was extremely effective for prevention of SSI in patients with compromised status, and it had no detection of cytotoxic or adverse effects on the patients.


Assuntos
Procedimentos Ortopédicos/efeitos adversos , Neoplasias da Coluna Vertebral/cirurgia , Coluna Vertebral/cirurgia , Infecção da Ferida Cirúrgica/epidemiologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Adulto Jovem
12.
PLoS One ; 9(10): e109838, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25333299

RESUMO

BACKGROUND: In total en bloc spondylectomy (TES) of upper thoracic spine including the second thoracic (T2) vertebra, T2 nerve roots are usually transected. In this study, we examined the association between transection of the T2 nerve roots and upper-extremity motor function in patients with upper thoracic TES. METHODS: We assessed 16 patients who underwent upper thoracic TES with bilateral transection of the T2 nerve roots. Patients were divided into three groups: 3 patients without any processing of T1 and upper nerve roots (T2 group), 7 with extensive dissection of T1 nerve roots (T1-2 group), and 6 with extensive dissection of T1 and upper nerve roots (C-T2 group). Postoperative upper-extremity motor function was compared between the groups. RESULTS: Postoperative deterioration of upper-extremity motor function was observed in 9 of the 16 patients (56.3%). Three of the 7 patients in the T1-2 group and all 6 patients in the C-T2 group showed deterioration of upper-extremity motor function, but there was no deterioration in the T2 group. In the T1-2 group, 3 patients showed mild deterioration that did not affect their activities of daily living and they achieved complete recovery at the latest follow-up examination. In contrast, severe dysfunction occurred frequently in the C-T2 group, without recovery at the latest follow-up. CONCLUSIONS: The transection of the T2 nerve roots alone did not result in upper-extremity motor dysfunction; rather, the dysfunction is caused by the extensive dissection of the T1 and upper nerve roots. Therefore, transection of the T2 nerve roots in upper thoracic TES seems to be an acceptable procedure with satisfactory outcomes.


Assuntos
Atividades Cotidianas , Movimento/fisiologia , Procedimentos Ortopédicos/métodos , Raízes Nervosas Espinhais/cirurgia , Vértebras Torácicas/cirurgia , Extremidade Superior/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Coluna Vertebral/fisiopatologia , Neoplasias da Coluna Vertebral/cirurgia
13.
PLoS One ; 9(6): e98797, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24893004

RESUMO

BACKGROUND: Total en bloc spondylectomy (TES) is associated with a high complication rate because it is technically demanding and involves patients compromised by cancer. Specifically, perioperative complications are more likely to occur in patients receiving preoperative irradiation. We examined the perioperative complications associated with TES in patients receiving preoperative irradiation. METHODS: Seventy-seven patients underwent TES between May 2010 and April 2013. We performed a retrospective review of prospectively collected data for 50 patients with metastatic tumors of the thoracic spine, excluding patients with primary spinal tumors, lumbar spinal metastasis, and combined anterior and posterior approach TES. Patients were divided into 2 groups: those with preoperative irradiation (RT-TES group, 18 patients) and those without preoperative irradiation (TES group, 32 patients). The following perioperative complications, occurring within 2 months of surgery, were compared between the groups: intraoperative dural injuries, epidural hematomas, deep surgical-site infections, postoperative cerebrospinal fluid leakage, wound dehiscence, pleural effusions, and neurological deficits. RESULTS: Significant differences in patient characteristics were not observed between the RT-TES and TES groups. Perioperative TES complications occurred in 20/50 patients (40.0%). The complication rate in the RT-TES group was 77.8% (14 out of 18), threefold higher than the 18.8% (6 out of 32) in the TES group (P<0.01). The incidence of complications, including intraoperative dural injuries, postoperative cerebrospinal fluid leakage, wound dehiscence, and pleural effusions, was significantly higher in the RT-TES group (P<0.01). CONCLUSION: The perioperative complication rate associated with TES for spinal metastasis was significantly higher among patients receiving preoperative irradiation than among those not receiving preoperative irradiation.


Assuntos
Procedimentos Neurocirúrgicos/efeitos adversos , Neoplasias da Coluna Vertebral/cirurgia , Adulto , Idoso , Feminino , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Doenças da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia , Resultado do Tratamento , Adulto Jovem
14.
Radiol Phys Technol ; 6(2): 356-66, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23568337

RESUMO

We propose a strategy of individualized image acquisitions and treatment planning for respiratory-gated carbon-ion therapy. We implemented it in clinical treatments for diseases of mobile organs such as lung cancers at the Gunma University Heavy Ion Medical Center in June 2010. Gated computed tomography (CT) scans were used for treatment planning, and four-dimensional (4D) CT scans were used to evaluate motion errors within the gating window to help define the internal margins (IMs) and planning target volume for each patient. The smearing technique or internal gross tumor volume (IGTV = GTV + IM), where the stopping power ratio was replaced with the tumor value, was used for range compensation of moving targets. Dose distributions were obtained using the gated CT images for the treatment plans. The influence of respiratory motion on the dose distribution was verified with the planned beam settings using 4D CT images at some phases within the gating window before the adoption of the plan. A total of 14 lung cancer patients were treated in the first year. The planned margins with the proposed method were verified with clinical X-ray set-up images by deriving setup and internal motion errors. The planned margins were considered to be reasonable compared with the errors, except for large errors observed in some cases.


Assuntos
Carbono/uso terapêutico , Tomografia Computadorizada Quadridimensional , Radioterapia com Íons Pesados , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador , Mecânica Respiratória , Humanos , Órgãos em Risco/efeitos da radiação , Posicionamento do Paciente , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Dosagem Radioterapêutica
15.
Cancers (Basel) ; 3(4): 4046-60, 2011 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-24213124

RESUMO

Carbon ion radiotherapy (C-ion RT) offers superior dose conformity in the treatment of deep-seated tumors compared with conventional X-ray therapy. In addition, carbon ion beams have a higher relative biological effectiveness compared with protons or X-ray beams. C-ion RT for the first patient at Gunma University Heavy Ion Medical Center (GHMC) was initiated in March of 2010. The major specifications of the facility were determined based on the experience of clinical treatments at the National Institute of Radiological Sciences (NIRS), with the size and cost being reduced to one-third of those at NIRS. The currently indicated sites of cancer treatment at GHMC are lung, prostate, head and neck, liver, rectum, bone and soft tissue. Between March 2010 and July 2011, a total of 177 patients were treated at GHMC although a total of 100 patients was the design specification during the period in considering the optimal machine performance. In the present article, we introduce the facility set-up of GHMC, including the facility design, treatment planning systems, and clinical preparations.

16.
Med Dosim ; 34(1): 87-90, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19181261

RESUMO

The recent broad adoption of 4-D computed tomography (4DCT) scanning in radiotherapy has allowed the accurate determination of the target volume of tumors by minimizing image degradation caused by respiratory motion. Although the radiation exposure of the treatment beam is significantly greater than that of CT scans used for treatment planning, it is important to recognize and optimize the radiation exposure in 4DCT from the radiological protection point of view. Here, radiation exposure in 4DCT was measured with a 16 multidetector CT. Organ doses were measured using thermoluminescence radiation dosimeter chips inserted at respective anatomical sites of an anthropomorphic phantom. Results were compared with those with the helical CT scan mode. The effective dose measured for 4DCT was 24.7 mSv, approximately four times higher than that for helical CT. However, the increase in treatment accuracy afforded by 4DCT means its use in radiotherapy is inevitable. The patient exposure in the 4DCT could be of value by clarifying the advantage of the treatment planning using 4DCT.


Assuntos
Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Protocolos Clínicos , Humanos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica/normas , Dosimetria Termoluminescente
17.
Int J Radiat Oncol Biol Phys ; 69(1): 118-24, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17513064

RESUMO

PURPOSE: To investigate the efficacy of dose calculations at the computed tomography (CT)-based rectal point (CTRP) as a predictive factor for late rectal complications in patients with cervical carcinoma who were treated with a combination of high-dose-rate intracavitary brachytherapy and external beam radiotherapy. METHODS AND MATERIALS: Ninety-two patients with uterine cervical carcinoma undergoing definitive radiotherapy alone were retrospectively analyzed. The median follow-up time for all patients was 32 months (range, 13-60 months). The cumulative biologically effective dose (BED) was calculated at the rectal reference point as defined by the International Commission on Radiation Units and Measurements Report 38 (BED(RP)) and at the CTRP (BED(CTRP)). Late rectal complications were recorded according to the Radiation Therapy Oncology Group grading system. RESULTS: The late rectal complications were distributed as follows: Grade 0, 68 patients (74%); Grade 1, 20 patients (22%); Grade 2, 4 patients (4%). Univariate analysis showed that BED(RP), BED(CTRP), RP dose/point A dose ratio, and CTRP dose/point A dose ratio were significantly correlated with late rectal complications (p < 0.05). On multivariate analysis, patients with a rectal BED(CTRP) >/=140 Gy(3) presented with significantly greater frequency of rectal complications (p = 0.031). CONCLUSIONS: The present results suggest that BED(CTRP) is a useful predictive factor for late rectal complications.


Assuntos
Braquiterapia/efeitos adversos , Lesões por Radiação/diagnóstico por imagem , Reto/efeitos da radiação , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/radioterapia , Adenocarcinoma/patologia , Adenocarcinoma/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Carcinoma Adenoescamoso/patologia , Carcinoma Adenoescamoso/radioterapia , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/radioterapia , Feminino , Humanos , Pessoa de Meia-Idade , Lesões por Radiação/patologia , Dosagem Radioterapêutica , Reto/diagnóstico por imagem , Eficiência Biológica Relativa , Neoplasias do Colo do Útero/patologia
18.
Igaku Butsuri ; 26(4): 163-72, 2006.
Artigo em Japonês | MEDLINE | ID: mdl-17634735

RESUMO

In order to support a routine QA of the CT number for treatment planning, we developed a phantom and a sample holder for easy handling. At most particle radiotherapy facilities in Japan, the CT number is calibrated by the poly-binary calibration method using liquid samples of 100% ethanol and 40% K(2)HPO(4) which are set in a cylindrical water phantom. However it is hard to remove air bubbles from the calibration liquid sample and maintain its stable concentration for a long time. So much time is needed for QA of the CT number. The new sample holder, which we developed, was able to keep a stable concentration of the liquid for more than 300 days. Consequently, the CT number of each sample, which was set in a water equivalent solid phantom, was the same as the CT number in a water phantom within 7 HU. In addition, we developed software which could measure the CT number of each sample semi-automatically and could calculate the calibration coefficients between the CT number and water equivalent length (WEL). Using this software, we could check the calibration result instantly at the time of CT data acquisition. These tools should be useful to carry out calibration of the CT-WEL routinely in a short time.


Assuntos
Imagens de Fantasmas , Tomógrafos Computadorizados , Calibragem , Humanos , Japão , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
19.
Magn Reson Imaging ; 23(5): 691-4, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16051045

RESUMO

We developed a high radiation sensitive polymer gel by modifying the amounts of the gel components and the temperature for the gel preparation. We evaluated its relaxation time linearity against dose and compared the measured dose distribution with the calculated one. For the relaxation time-dose linearity, irradiations were carried out with a linear accelerator using 6 MV photons and doses ranging from 0-5.0 Gy. The relationship between dose and R(2) value (reciprocal of T(2) relaxation time) was measured and it had good linearity over a wide range (0.3-5 Gy). The measured dose distributions were in good agreement with calculated ones. Since the present gel has higher sensitivity and it is synthesized more easily at lower cost than conventional polymer gels, we expect to see improved three-dimensional (3D) dosimetry using it.


Assuntos
Géis/química , Imageamento por Ressonância Magnética/métodos , Polímeros/química , Radiometria/instrumentação , Relação Dose-Resposta à Radiação , Doses de Radiação , Dosagem Radioterapêutica , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA